Light Commercial Steam Heating System Energy Economizer
IntelliCon LCS 1120
The LCS is a microprocessor-controlled, fuel-saving device for light-commercial steam heating systems rated up to 2.5 mm BTU/hr. The LCS reduces fuel consumption, wear on parts, flue emissions and electrical usage, when installed on any new or existing gas, propane, or oil burner. The LCS saves energy by adjusting the burner run pattern to match the system’s “heat load.” Its action is similar to the industry-accepted method of “outdoor-air temperature reset control,” but does not require an outdoor-air temperature sensor or the need to profile the building in order to adjust the “reset” controller properly. The LCS determines the “heat load” by using an easily installed pressure sensor that monitors the boiler’s steam-pressure and the rate that this pressure is changing.
Features
Features
- Patented process reduces fuel consumption—typically 10% to 30%
- UL listed, “Energy Management Equipment”
- Increased savings without replacing or upgrading costly system components
- “State-of-the-art” microcomputer controller
- For commercial systems rated up to 2.5 million BTU
- LCD display shows operating modes, diagnostics, system pressure/temperature, and economizing time
- Easily installed plug-in sensor(s) (ordered separately)
- Simple installation by qualified installer
- Easily programmed and no follow-up visits required
- Maximum year-round efficiency
- Reduces maintenance and extends boiler life
- Fail-safe operation
- Guaranteed to save energy
- 15-year replacement Global warranty for breakdowns or defects
Specifications
Specifications
- Mounting in any position via molded-on 1/2" Electrical Fitting
- Size: 4"H x 4"W x 2 1/2"D
- Operating Humidity: 5% - 95% Non-Condensing
- Power Input: 24/115/220 VAC @ 5W
- Control Circuit: 24 VAC/DC, 115/220 VAC
- Relay Contact: 10A @ 220VAC General Purpose
- Steam Pressure Sensor Sold Separately
- Made in USA
Accessories
Accessories
- Low Pressure Steam Sensor 2-25 PSI (4006)
- High Pressure Steam Sensor 26-145 PSI (4005)
- Remote Display Unit (4075) System 12®
- Rain-Tight Enclosure Plastic (4065)
- Iron Pigtail (4050)
IntelliCon LCH
The LCH is a microprocessor-based, fuel-saving control for light-commercial hot-water (hydronic) heating systems. The LCH reduces fuel consumption, wear on parts, flue emissions and electrical usage, when installed on any new or existing gas or oil burner. The LCH saves energy by adjusting the burner run pattern to match the system’s “heat load”. Its action is similar to the industry-accepted method of “outdoor-air temperature reset control,” but does not require an outdoor-air temperature sensor or the need to profile the building in order to adjust the “reset” controller properly. The LCH determines the “heat load” by using an easily installed strap-on temperature sensor that monitors the boiler’s out-flow water temperature and the rate this temperature is changing.
Features
Features
- For commercial systems rated up to 2.5 million BTU / hr
- Illuminated LCD display shows fuel consumption savings, operating modes, system diagnostics and operating temperatures
- Patented process reduces fuel consumption—typically 10% to 20%
- UL listed, “Energy Management Equipment”
- Increased savings without replacing or upgrading costly system components
- “State-of-the-art” microcomputer controller
- Easily installed plug-in sensor(s) (includes 1 required sensor)
- Simple installation by qualified installer
- Easily programmed and no follow-up visits required
- Maximum year-round efficiency
- Reduces maintenance and extends boiler life
- Fail-safe operation
- Guaranteed to save energy
- 15-year replacement warranty for breakdowns or defects
Specifications
Specifications
- Mounting in any position via molded-on 1/2" Electrical Fitting
- Size: 4"H x 4"W x 2 1/2"D
- Operating Humidity: 5% - 95% Non-Condensing
- Operating TemperatureRange: -10°F - +120°F
- Power Input: 24/115/220 VAC @ 5W
- Control Circuit: 24 VAC/DC, 115/220 VAC
- Relay Contact: 10A @ 220VAC General Purpose
- Made in USA
Accessories
Accessories
- 10’ Hydronic Temperature Sensor (4001A)
- 20’ Hydronic Temperature Sensor (4002A)
- Remote Display Unit (4075)
- Rain-Tight Enclosure Plastic (4065)
IntelliCon CAC 2400 
The CAC 2400 typically reduces Commercial Air Conditioning electric consumption by 10% to 30% or more. The CAC is a microprocessor-based, UL listed, electronic control that uses intelligent Dynamic Cycle Management® (DCM) technology to automatically adjust the compressor cycles to achieve the greatest efficiency and reduced electrical usage, while assuring consistent temperature levels. The CAC is maintenance free, easy to install by a qualified installer, and is guaranteed to save energy and Money.
Features
Features
- Dynamic Cycle Management® (DCM) technology reduces air conditioning electric consumption—typically 10% to 30% or more
- Compatible with Heat Pump systems
- “Energy Management Equipment”
- Increased savings without replacing or upgrading costly system components
- State-of-the-art microprocessor based control—Illuminated LCD display shows run time hours, economizing hours, operating modes and system diagnostics
- For systems 4 tons or larger
- Protects compressor against momentary power outages and short cycling
- Simple installation by a qualified HVAC/R installer
- Easily programmed and no follow-up visits required
- Maximum year-round efficiency
- Reduces maintenance and extends compressor life
- Fail-safe operation
- Guaranteed to save energy
- 15-year replacement Global warranty for breakdowns or defects
Specifications
Specifications
- Mounting in any position via molded-on 1/2" Electrical Fitting
- Size: 4"H x 4"W x 2 1/2"D
- Operating Humidity: 5% - 95% Non-Condensing
- Operating TemperatureRange: -10°F - +120°F
- Power Input: 24/115/220 VAC @ 5W
- Control Circuit: 24 VAC/DC, 115/220 VAC
- Relay Contact: 10A @ 220VAC General Purpose
- Made in USA
Accessories
Accessories
- Remote Display Unit (4075) System 12 (RUD LED Display)
- Universal Resistor Kit (4070)
- Rain-Tight Enclosure (4065)


Learn More...